Availability: | |
---|---|
Quantity: | |
DL6000iOE
DRIVELONG
Innovative Energy-saving 5kw Construction Silent Fuel Inverter Generator
innovation, low clamor, eco-friendly, smaller and compact plan, over-burden assurance, low oil closure, electric beginning, simple support, appropriate for building locales, open air occasions, and crisis reinforcement power.
Presenting the 5kw Development Fuel Inverter Generator, a dependable and strong answer for all your power needs. With its DL6000iOE evaluated force of 5000W and top force of 5500W, this generator is fit for giving a consistent and proficient power supply.
Including keen choking recurrence transformation innovation, this generator guarantees an unadulterated sine wave voltage yield, making it protected and reasonable for delicate gadgets and machines. The multi-shaft super durable magnet generator recurrence transformation innovation further improves its presentation, giving steady and solid power.
One of the champion elements of this generator is its low commotion activity. With cutting edge sound decrease innovation, it works unobtrusively, limiting aggravations in the general climate. This makes it ideal for use in building locales, open air occasions, and other commotion delicate regions.
Not exclusively is this generator strong and calm, however it is additionally eco-friendly. Its astute choking innovation guarantees that fuel utilization is advanced, taking into consideration longer run times without the requirement for successive refueling. This isn't just practical yet additionally advantageous, particularly in circumstances where admittance to fuel might be restricted.
The smaller and convenient plan of this generator adds to its flexibility. It is not difficult to ship and store, pursuing it a helpful decision for both on location and off-site power needs. Whether you really want it for development projects, open air occasions, or as a reinforcement power source during crises, this generator is intended to meet your prerequisites.
Security is a main concern, and this generator is outfitted with different wellbeing highlights. It accompanies over-burden assurance, forestalling harm to the generator and associated gadgets in the event of force floods or exorbitant burdens. Furthermore, it has a low oil closure highlight, naturally closing down the generator when oil levels are low, safeguarding the motor from harm.
With electric beginning usefulness, beginning the generator is fast and bother free. This takes out the requirement for manual pulling, making it more straightforward for anybody to work. Moreover, the generator is intended for simple upkeep, guaranteeing that it stays in ideal condition for dependable execution.
In rundown, the 5kw Development Gas Inverter Generator is a strong, productive, and solid answer for all your power needs. Its shrewd choking recurrence transformation innovation, unadulterated sine wave voltage yield, low clamor activity, eco-friendliness, smaller plan, and security highlights settle on it an incredible decision for building destinations, open air occasions, and crisis reinforcement power. Put resources into this generator and experience the accommodation and inner harmony it offers.
DLiO SERIES SPECIFICATIONS
GENSET
Model | DL3500iO | DL6000iOE | DL8000iOE |
Overall Length | 502mm | 605mm | 605mm |
Overall Width | 350mm | 514mm | 514mm |
Overall Height | 495mm | 537mm | 537mm |
Dry Weight | 30kg | 60kg | 65kg |
ENGINE
Type | 4-stroke gasoline OHV | 4-stroke gasoline OHV | 4-stroke gasoline OHV | |
Cooling System | Forced air | Forced air | Forced air | |
Cylinder Arrangement | Inclined, single cylinder | Inclined, single cylinder | Inclined, single cylinder | |
Displacement | 212cm3 | 301cm3 | 420cm3 | |
Bore×Stroke | 70mm×55mm | 80mm×60mm | 90mm×66mm | |
Operation Hours | 4Hr@rated load | 5Hr@rated load | 3.5Hr@rated load | |
7Hr@1/2 rated load | 9Hr@1/2 rated load | 6Hr@1/2 rated load | ||
Fuel | Unleaded gasoline | Unleaded gasoline | Unleaded gasoline | |
Fuel Tank Capacity | 7L | 16L | 16L | |
Engine Oil Capacity | 0.6L | 1L | 1L | |
Ignition System | CDI | CDI | CDI | |
Starting System | Recoil | Recoil & Electric starter / APP starter | Recoil & Electric starter / APP starter | |
Spark Plug | Type | F7RTC | F7RTC | F7RTC |
Gap | 0.7~0.8mm | 0.7~0.8mm | 0.7~0.8mm | |
Noise Pressure Level(LPA) @ From 7m | 67~76dB(A) | 70~78dB(A) | 73~84dB(A) |
GENERATOR
AC Output | Output Waveform | Inverter, Pure-Sine Wave, THD <3% | Inverter, Pure-Sine Wave, THD <3% | Inverter, Pure-Sine Wave, THD <3% |
Rated Voltage | 100/110/120/220/230/240V | 100/110/120/220/230/240V | 100/110/120/220/230/240V | |
Rated Frequency | 60/50Hz | 60/50Hz | 60/50Hz | |
Rated Output | 3.2kVA | 5.0kVA | 7.0kVA | |
Maximum Output | 3.5kVA | 5.5kVA | 7.5kVA | |
Safety Device Type | Electronic | Electronic | Electronic | |
DC Output | Rated Voltage | 12V | 12V | 12V |
Rated Current | 8.3A | 8.3A | 8.3A | |
USB | 5V/2A/1A | 5V/2A/1A | 5V/2A/1A | |
Safety Device Type | DC Protector | DC Protector | DC Protector |
NOTE
The generator output specifications are based on the standard environment as follows:
l Altitude: 0m
l Ambient temperature: 25℃
l Relative humidity: 30%